Our Services
One-on-One Customer Service
Analytics Labs takes pride in having top-ranking customer service. Our dedicated Project Management Team will provide the highest level of personalized service that is unmatched in New England. The Project Managers will work closely with our scientific crew to maintain consistent turnaround times. We understand the uniqueness of each client and will be committed wholeheartedly to maintain all of our clients needs. It is our goal to make each client feel like they are our only client.
Sample Pick Up
Analytics Labs understands your time is money and we are committed to minimizing your time in testing preparation. Therefore, if you are not able to drop samples off at the lab we will guarantee same day pick ups. We are dedicated to maintaining client timelines while preserving the highest quality laboratory processes.
Sample Drop Off
Analytics Labs is conveniently located in the heart of Holyoke MA. We openly invite you to drop off samples at the lab. While you are here we encourage you to take a quick tour of the facility and learn about our processes. We are excited to answer any questions, describe our procedures, and if you are so inclined, we will teach you how the instruments work. Education is key to unlocking the enigma of cannabis laboratories.

Analysis
Pricing available upon request. Discounts based on volume and frequency of testing.
Cannabinoid Profile
Required for:
- Finished Plant Material at Final Point of Sale
- Resin and Concentrates at Final Point of Sale
- ALL Marijuana Infused Products (MIPs)
Recommended for:
ALL Resin and Concentrates
Amount of Sample Needed:
- Finished Plant 1 gram
- Concentrate/Resin: 0.5 grams
- MIPs: 1 serving (at least 1 gram)
Analytes
- Δ9-THC
- Δ8-THC
- THCa
- THCV
- CBD
- CBDa
- CBDV
- CBDVa
- CBG
- CBGa
- CBN
- CBC
Action Level
None
Analysis Method
High-Performance Liquid Chromatography with Diode-Array Detector (HPLC-DAD)
Reference Material
- American Herbal Pharmacopoeia (AHP 2013)
- United Nations Office on Drugs and Crime (UNODC 2009)
- EPA 548.1
- AOAC SMPR 2017.001
- AOAC SMPR 2017.002
- AOAC SMPR 2017.019
Terpene Profile
Required for:
Any Products with Additives
Recommended for:
- Finished Plant Material at Final Point of Sale
- Resin and Concentrates at Final Point of Sale
Amount of Sample Needed:
- Finished Plant 1 gram
- Concentrate/Resin: 0.5 grams
- MIPs: 1 serving (at least 1 gram)
Analytes
- ɑ-pinene
- Camphene
- β-Pinene
- β-Myrcene
- 3-Carene
- ɑ-Terpinene
- p-Cymene
- Limonene
- Ocimene
- Ɣ-Terpinene
- Terpinolene
- Linalool
- Isopulegol
- Geraniol
- β-Caryophyllene
- ɑ-Humulene
- Nerolidol
- Caryophyllene Oxide
- Guaiol
- ɑ-Bisabolol
Action Level
None
Analysis Method
Gas Chromatography with Flame Ionization Detector (GC-FID)
Reference Material
- ASTM WK54014
- ASTM D6387 – 19
- ASTM D3009
- ASTM D6387 -99(2014)e1
Moisture Content
Required for:
None
Recommended for:
Finished Plant Material at Final Point of Sale
Amount of Sample Needed:
Finished Plant 1 gram
Action Level
None
Analysis Method
Moisture Reader
Reference Material
- USP <921>
- ASTM D2216 – 98
Heavy Metals
Required for:
- Finished Plant Material at Final Point of Sale
- ALL Resin and Concentrates
Amount of Sample Needed:
- Finished Plant 1 gram
- Concentrate/Resin: 0.5 grams
- MIPs: 1 serving (at least 1 gram)
Analytes
- Arsenic (As)
- Cadmium (Cd)
- Lead (Pb)
- Mercury (Hg)
Action Limit for ingestion only
- As: <1,500ppb
- Cd: <500ppb
- Pb: <1,000ppb
- Hg: <1,500ppb
Action Limit for all non-ingested products
- As: <200ppb
- Cd: <200ppb
- Pb: <500ppb
- Hg: <100ppb
Analysis Method
Inductively Coupled Plasma Mass Spectrometry (ICP-MS)
Reference Material
- USP <233>
- USP <232>
- UPS <2232>
- FDA EAM 4-7
- AOAC 2017.02
- EPA 6020A
Pesticides
Required for:
ALL Finished Plant Material
Amount of Sample Needed:
Finished Plant 1 gram
Analytes
- Bifenazate
- Bifenthrin
- Cyfluthrin
- Etoxazole
- Imazalil
- Imidacloprid
- Myclobutanil
- Spiromesifen
- Trifloxystrobin
Action Limit
10 ppb or 5% of EPA established tolerance of residue
Analysis Method
Liquid Chromatography with tandem Mass Spectrometry (LCMS-MS)
Reference Material
- American Herbal Pharmacopoeia (AHP 2013)
- EPA1694
- AOAC SMPR 2018.011 (Validation Guidelines)
Pathogenic Microbiological Analysis
Required for:
- Finished Plant Material at Final Point of Sale
- Resin and Concentrates at Final Point of Sale
- ALL Marijuana Infused Products (MIPs)
Amount of Sample Needed:
- Finished Plant 1.5 gram
- Concentrate/Resin: 1.5 grams
- MIPs: 1 serving (at least 1 gram)
Analytes
- E. coli (Escherichia coli)
- Salmonella
Action Limit
Not Detected in 1 gram
Analysis Method
Real-Time Polymerase Chain Reaction (RT qPCR)
Reference Material
- American Herbal Pharmacopoeia (AHP 2013)
- USP <561>
- FDA Bacteriological Analytical Manual (BAM)
- AOAC OMA 2017.06
Non-Pathogenic Microbiological Analysis
Required for:
- Finished Plant Material at Final Point of Sale
- Resin and Concentrates at Final Point of Sale
- ALL Marijuana Infused Products (MIPs)
Amount of Sample Needed:
- Finished Plant 1.5 gram
- Concentrate/Resin: 1.5 grams
- MIPs: 1 serving (at least 1 gram)
Analytes
- Aerobic
- Total Yeast and Mold
- Total Coliforms and E. coli
- Bile Tolerant Gram-Negative
Action Limit
- Aerobic: <100,000 CFU/g
- Total Yeast and Mold: <10,000 CFU/g
- Total Coliforms and E. coli: <1,000 CFU/g
- Bile Tolerant Gram-Negative: <1,000 CFU/g
Analysis Method
3M Petrifilm
Reference Material
- American Herbal Pharmacopoeia (AHP 2013)
- FDA Bacteriological Analytical Manual (BAM)
- USP <62>
- AOAC 2015.13
- AOAC 991.14
- AOAC 2003.01
- AOAC 2014.05
Mycotoxins
Required for:
- Finished Plant Material at Final Point of Sale
- Resin and Concentrates at Final Point of Sale
- ALL Marijuana Infused Products (MIPs)
Amount of Sample Needed:
- Finished Plant 1 gram
- Concentrate/Resin: 0.5 grams
- MIPs: 1 serving (at least 1 gram)
Analytes
- Aflatoxin B1
- Aflatoxin B2
- Aflatoxin G1
- Aflatoxin G2
Action Limit
Aflatoxin Sum <20 ppb
Analysis Method
Liquid Chromatography with tandem Mass Spectrometry (LCMS-MS)
Reference Material
- American Herbal Pharmacopoeia (AHP 2013)
- FDA Bacteriological Analytical Manual (BAM)
- USP <62>
- AOAC 2015.13
- AOAC 991.14
- AOAC 2003.01
Residual Solvents
Required for:
ALL Concentrate/Resin
Amount of Sample Needed:
Concentrate/Resin: 0.5 grams
Analytes
- Propane
- iso-butane
- n-Butane
Action Limit
< 1ppm
Analysis Method
Gas Chromatography with Flame Ionization Detector (GC-FID)
Reference Material
- USP <467>
- USP <621>
- USP <736>
- EPA 8000D
- EPA 8015D